Review



reversed phase column  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Danaher Inc reversed phase column
    Reversed Phase Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1675 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Kinetex+Core-Shell+Technology+Columns/pm43044928-125-8-18
    Average 99 stars, based on 1675 article reviews
    reversed phase column - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    Fluorescence:

    Article Title: Genotype-specific antioxidant, reactive-carbonyl, and polyamine responses underlying heat tolerance in six winter wheat cultivars
    Article Snippet: .. This was done using a W2690 separation module on a reversed-phase column (Kinetex C18, 5 μm, 100 mm × 4.6 mm, Phenomenex, Torrance, CA, United States) and a W474 scanning fluorescence detector with excitation at 340 nm and emission at 515 nm (Waters, Milford, MA, USA). ..

    Article Title: Size-Dependent Zinc Delivery and Nanozyme-Mediated Stress Alleviation by ZnO Nanoparticles in Zinc-Deficient Tomato.
    Article Snippet: .. The analysis of dansylated PAs, namely, 1,3- diaminopropane (DAP), putrescine (PUT), spermidine (SPD), and spermine (SPM), was carried out according to Paĺ et al.48 via HPLC using a W2690 separation module on a reversed-phase column (Kinetex C18, 5 μm, 100 × 4.6 mm, Phenomenex, Inc.) and a W474 scanning fluorescence detector with excitation at 340 nm and emission at 515 nm (Waters, Milford, MA, USA). ..

    Fractionation:

    Article Title: Targeted Lipidomics Insights into Lipid Discrepancies in Chicken Embryonic Brains Under Hypoxia Based on UHPLC-QTRAP-MS
    Article Snippet: Lipid profiling was implemented on an ultra-high-performance liquid chromatography platform (LC-30AD, Shimadzu Corporation, Kyoto, Japan) interfaced with a QTRAP 6500+ mass spectrometer (Sciex, Framingham, MA, USA). .. Two orthogonal separation columns were deployed for lipid fractionation: a Luna NH 2 HILIC column (2.0 mm × 100 mm, 3 μm; Phenomenex, Torrance, CA, USA) and a Kinetex C18 reversed-phase column (2.1 mm × 100 mm, 2.6 μm; Phenomenex, Torrance, CA, USA). ..

    Hydrophilic Interaction Liquid Chromatography:

    Article Title: Targeted Lipidomics Insights into Lipid Discrepancies in Chicken Embryonic Brains Under Hypoxia Based on UHPLC-QTRAP-MS
    Article Snippet: Lipid profiling was implemented on an ultra-high-performance liquid chromatography platform (LC-30AD, Shimadzu Corporation, Kyoto, Japan) interfaced with a QTRAP 6500+ mass spectrometer (Sciex, Framingham, MA, USA). .. Two orthogonal separation columns were deployed for lipid fractionation: a Luna NH 2 HILIC column (2.0 mm × 100 mm, 3 μm; Phenomenex, Torrance, CA, USA) and a Kinetex C18 reversed-phase column (2.1 mm × 100 mm, 2.6 μm; Phenomenex, Torrance, CA, USA). ..

    Analysis:

    Article Title: Size-Dependent Zinc Delivery and Nanozyme-Mediated Stress Alleviation by ZnO Nanoparticles in Zinc-Deficient Tomato.
    Article Snippet: .. The analysis of dansylated PAs, namely, 1,3- diaminopropane (DAP), putrescine (PUT), spermidine (SPD), and spermine (SPM), was carried out according to Paĺ et al.48 via HPLC using a W2690 separation module on a reversed-phase column (Kinetex C18, 5 μm, 100 × 4.6 mm, Phenomenex, Inc.) and a W474 scanning fluorescence detector with excitation at 340 nm and emission at 515 nm (Waters, Milford, MA, USA). ..

    High Performance Liquid Chromatography:

    Article Title: Size-Dependent Zinc Delivery and Nanozyme-Mediated Stress Alleviation by ZnO Nanoparticles in Zinc-Deficient Tomato.
    Article Snippet: .. The analysis of dansylated PAs, namely, 1,3- diaminopropane (DAP), putrescine (PUT), spermidine (SPD), and spermine (SPM), was carried out according to Paĺ et al.48 via HPLC using a W2690 separation module on a reversed-phase column (Kinetex C18, 5 μm, 100 × 4.6 mm, Phenomenex, Inc.) and a W474 scanning fluorescence detector with excitation at 340 nm and emission at 515 nm (Waters, Milford, MA, USA). ..



    Similar Products

    99
    Danaher Inc reversed phase column
    Reversed Phase Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Kinetex+Core-Shell+Technology+Columns/pm43044928-125-8-18
    Average 99 stars, based on 1 article reviews
    reversed phase column - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Danaher Inc reverse phase chromatographic column
    Reverse Phase Chromatographic Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Luna+High+Performance+LC+Columns/pmc13777419-74-6-9
    Average 99 stars, based on 1 article reviews
    reverse phase chromatographic column - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    95
    Agilent technologies reversed phase chromatography column
    Reversed Phase Chromatography Column, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/ZORBAX+RRHD+300SB/pmc13769033-314-3-6
    Average 95 stars, based on 1 article reviews
    reversed phase chromatography column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    93
    Danaher Inc onyx monolithic reverse phase c 18 column
    Onyx Monolithic Reverse Phase C 18 Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Onyx+Monolithic+HPLC+Columns/bio_rxiv__64898__2026__11__10__765661-215-7-6
    Average 93 stars, based on 1 article reviews
    onyx monolithic reverse phase c 18 column - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    95
    Agilent technologies phase c18 column
    Phase C18 Column, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Bio+LC/10__3390_slash_agronomy16212234-91-10-20
    Average 95 stars, based on 1 article reviews
    phase c18 column - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    97
    IonOpticks nlc ms ms analysis nano reversed phase columns
    Nlc Ms Ms Analysis Nano Reversed Phase Columns, supplied by IonOpticks, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Aurora+Ultimate+25x75/pm42992678-148-0-6
    Average 97 stars, based on 1 article reviews
    nlc ms ms analysis nano reversed phase columns - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    98
    Danaher Inc reversed phase c4 column
    Chromatographic profile on a <t>C18</t> <t>reversed-phase</t> column and mass spectra of the different peptides produced. The synthetic peptides were purified in semipreparative mode using a Beckman System Gold HPLC with a C18 reversed-phase column (2.1 cm × 25 cm). Purity levels of the fractions were assessed on a Shimadzu chromatograph with an analytical C18 reversed-phase column (0.46 cm × 25 cm). The solvents employed for purification and purity analysis were 0.045% TFA in deionized water (Solvent A) and 0.036% TFA in acetonitrile (Solvent B). Mass spectra were acquired with an ion trap mass spectrometer using electrospray ionization (ESI). (A) and (D) Lmr-BPP-9 (WPPRPQIPP); (B) and (E) Bj-BPP-10c (ENWPHPQIPP); and (C) and (F) TsHpt-I 17–25 (KETNAKPPA).
    Reversed Phase C4 Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Jupiter+HPLC+Columns/pmc13784032-71-11-24
    Average 98 stars, based on 1 article reviews
    reversed phase c4 column - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    94
    IonOpticks reversed phase c18 analytical column
    Chromatographic profile on a <t>C18</t> <t>reversed-phase</t> column and mass spectra of the different peptides produced. The synthetic peptides were purified in semipreparative mode using a Beckman System Gold HPLC with a C18 reversed-phase column (2.1 cm × 25 cm). Purity levels of the fractions were assessed on a Shimadzu chromatograph with an analytical C18 reversed-phase column (0.46 cm × 25 cm). The solvents employed for purification and purity analysis were 0.045% TFA in deionized water (Solvent A) and 0.036% TFA in acetonitrile (Solvent B). Mass spectra were acquired with an ion trap mass spectrometer using electrospray ionization (ESI). (A) and (D) Lmr-BPP-9 (WPPRPQIPP); (B) and (E) Bj-BPP-10c (ENWPHPQIPP); and (C) and (F) TsHpt-I 17–25 (KETNAKPPA).
    Reversed Phase C18 Analytical Column, supplied by IonOpticks, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/reversed+phase+column/Odyssey+Elite+15x75/bio_rxiv__64898__2026__11__02__763559-307-8-12
    Average 94 stars, based on 1 article reviews
    reversed phase c18 analytical column - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    Image Search Results


    Chromatographic profile on a C18 reversed-phase column and mass spectra of the different peptides produced. The synthetic peptides were purified in semipreparative mode using a Beckman System Gold HPLC with a C18 reversed-phase column (2.1 cm × 25 cm). Purity levels of the fractions were assessed on a Shimadzu chromatograph with an analytical C18 reversed-phase column (0.46 cm × 25 cm). The solvents employed for purification and purity analysis were 0.045% TFA in deionized water (Solvent A) and 0.036% TFA in acetonitrile (Solvent B). Mass spectra were acquired with an ion trap mass spectrometer using electrospray ionization (ESI). (A) and (D) Lmr-BPP-9 (WPPRPQIPP); (B) and (E) Bj-BPP-10c (ENWPHPQIPP); and (C) and (F) TsHpt-I 17–25 (KETNAKPPA).

    Journal: Biochemistry

    Article Title: Synthesis and PEGylation Strategy for Bradykinin-Potentiating Peptides from Animal Venoms

    doi: 10.1021/acs.biochem.6c00317

    Figure Lengend Snippet: Chromatographic profile on a C18 reversed-phase column and mass spectra of the different peptides produced. The synthetic peptides were purified in semipreparative mode using a Beckman System Gold HPLC with a C18 reversed-phase column (2.1 cm × 25 cm). Purity levels of the fractions were assessed on a Shimadzu chromatograph with an analytical C18 reversed-phase column (0.46 cm × 25 cm). The solvents employed for purification and purity analysis were 0.045% TFA in deionized water (Solvent A) and 0.036% TFA in acetonitrile (Solvent B). Mass spectra were acquired with an ion trap mass spectrometer using electrospray ionization (ESI). (A) and (D) Lmr-BPP-9 (WPPRPQIPP); (B) and (E) Bj-BPP-10c (ENWPHPQIPP); and (C) and (F) TsHpt-I 17–25 (KETNAKPPA).

    Article Snippet: The PEGylated form of the synthetic peptides was purified on a reversed-phase C4 column (Jupiter, 5 μm, 300 Å, 250 mm × 4.6 mm, Phenomenex), previously equilibrated with 0.1% TFA.

    Techniques: Produced, Purification, Analysis, Solvent, Mass Spectrometry

    Chromatographic profiles of synthetic and synthetic PEGylated peptides obtained by FPLC. A C18 reversed-phase analytical column (2.1 mm × 250 mm) was pre-equilibrated with 0.1% (v/v) TFA, with a flow rate of 0.4 mL/min. The profiles were monitored at 214 nm (blue line), while the green line represents the gradient of Solution B (0.1% TFA + 80% acetonitrile). (A) Synthetic Lmr-BPP-9. (B) PEG-Lmr-BPP-9. (C) Synthetic TsHpt-I 17–25 . (D) PEG-TsHpt-I 17–25 . (E) Synthetic Bj-BPP-10c. (F) PEG-Bj-BPP-10c. (G) Chromatographic profile of PEG and sodium cyanoborohydride (NaCNBH 3 ).

    Journal: Biochemistry

    Article Title: Synthesis and PEGylation Strategy for Bradykinin-Potentiating Peptides from Animal Venoms

    doi: 10.1021/acs.biochem.6c00317

    Figure Lengend Snippet: Chromatographic profiles of synthetic and synthetic PEGylated peptides obtained by FPLC. A C18 reversed-phase analytical column (2.1 mm × 250 mm) was pre-equilibrated with 0.1% (v/v) TFA, with a flow rate of 0.4 mL/min. The profiles were monitored at 214 nm (blue line), while the green line represents the gradient of Solution B (0.1% TFA + 80% acetonitrile). (A) Synthetic Lmr-BPP-9. (B) PEG-Lmr-BPP-9. (C) Synthetic TsHpt-I 17–25 . (D) PEG-TsHpt-I 17–25 . (E) Synthetic Bj-BPP-10c. (F) PEG-Bj-BPP-10c. (G) Chromatographic profile of PEG and sodium cyanoborohydride (NaCNBH 3 ).

    Article Snippet: The PEGylated form of the synthetic peptides was purified on a reversed-phase C4 column (Jupiter, 5 μm, 300 Å, 250 mm × 4.6 mm, Phenomenex), previously equilibrated with 0.1% TFA.

    Techniques:

    Mass spectrometry of peaks obtained from C18 reversed-phase liquid chromatography of synthetic peptides. Spectra were acquired using a MALDI-TOF/TOF UltrafleXtreme mass spectrometer (Bruker Daltonics). Lmr-BPP-9: (A) Peak 1, (B) Peak 2, and (C) Peak 3; TsHpt-I 17–25 : (D) Peak 1, (E) Peak 2, and (F) Peak 3; Bj-BPP-10c: (G) Peak 1, (H) Peak 2, and (I) Peak 3.

    Journal: Biochemistry

    Article Title: Synthesis and PEGylation Strategy for Bradykinin-Potentiating Peptides from Animal Venoms

    doi: 10.1021/acs.biochem.6c00317

    Figure Lengend Snippet: Mass spectrometry of peaks obtained from C18 reversed-phase liquid chromatography of synthetic peptides. Spectra were acquired using a MALDI-TOF/TOF UltrafleXtreme mass spectrometer (Bruker Daltonics). Lmr-BPP-9: (A) Peak 1, (B) Peak 2, and (C) Peak 3; TsHpt-I 17–25 : (D) Peak 1, (E) Peak 2, and (F) Peak 3; Bj-BPP-10c: (G) Peak 1, (H) Peak 2, and (I) Peak 3.

    Article Snippet: The PEGylated form of the synthetic peptides was purified on a reversed-phase C4 column (Jupiter, 5 μm, 300 Å, 250 mm × 4.6 mm, Phenomenex), previously equilibrated with 0.1% TFA.

    Techniques: Mass Spectrometry, Reversed-phase Liquid Chromatography